Marstek Venus D All-in-One Balcony Power Plant with Storage
Note: At least one battery is required for operation.
Note: The expected shipping date after purchase is January 5th.
We deliver directly to your home free of charge.*
Delivery usually takes 7-14 working days*, so just sit back and relax.
*More information can be found in the shipping conditions .
We guarantee a 14-day return policy. This means that, regardless of the reason, you can cancel your order within 14 days. As soon as we receive your return in its undamaged original packaging, we will process your refund immediately.
Please note that any costs incurred during a return or refund – such as PayPal's 2% transaction fee and return shipping costs – will be retained as a fee. This fee covers payment and processing costs.
*For more information on the conditions for a successful refund process, please see our refund policy .
Marstek.de offers a 10-year warranty. Should the product fail within this period due to material or manufacturing defects, we will provide a replacement. The replacement product will be covered for the remaining warranty period of the original item.
To make a warranty claim, please contact our customer service at: support@marstekenergy.com .
*Further details can be found in our warranty conditions.
We're happy to help! If you have any questions or suggestions, please write to us at support@marstek.de – our team will take care of your request immediately.

<15 ms EPS switching
Switches to emergency power within 15 ms and ensures uninterrupted operation.

2.2 kW emergency power supply
Provides reliable emergency power supply for critical equipment, with short peak loads up to 2.5 kW.
<15 ms EPS switching
Switches to emergency power within 15 ms and ensures uninterrupted operation.
2.2 kW emergency power supply
Provides reliable emergency power supply for critical equipment, with short peak loads up to 2.5 kW.


| Model: Marstek Venus D | |
|---|---|
| DC: Photovoltaic input | |
| Maximum input power | 4000 W |
| MPPT voltage range | 16-55 V |
| MPPT start voltage | 22 V |
| Operating voltage range | 16-60 V |
| Max. input voltage | 60 V |
| Max. input current (single channel) | 32 A |
| Max. input short-circuit current (single channel) | 40 A |
| Number of PV input channels | 4 |
| MPPT tracking amount | 4 |
| AC: Mains-connected input | |
| Nominal input power | 2200 VA |
| operational phase | L/N/PE |
| Nominal mains voltage | 230 V |
| Nominal mains frequency | 50 Hz |
| Nominal mains input current | 9.57 A |
| Performance factor | >0.99 Standard |
| AC: Mains-connected output | |
| Nominal output power | 800 VA/2200 VA |
| operational phase | L/N/PE |
| Nominal mains voltage | 230 V |
| Nominal mains frequency | 50 Hz |
| Nominal mains output current | 3.48 A/9.57 A |
| Performance factor | >0.99 Standard |
| THDi | < 3% |
| AC: Standalone output | |
| Nominal output power | 2200 VA |
| Top performance | 2500 VA |
| Rated current | 9.57 A |
| Nominal voltage | 230 V |
| Rated frequency | 50 Hz |
| THDu | < 3% |
| Miscellaneous | |
| Grid-connected AC power connection | Three-wire household plug (Euro16A) |
| Advertisement | LED light strip display |
| Communication methods | Bluetooth, WLAN, RS-485 (RJ45), Ethernet port (RJ45) |
Note 1: The nominal voltage/frequency range may be changed according to the requirements of the local energy supplier.
Note 2: Please refer to local electrical regulations to determine the number of MARSTEK VENUS units that can be connected to each branch circuit.
*Activating this function must comply with local regulations and should only be performed by authorized personnel!
Included in the scope of delivery
Marstek Venus D
AC cable
Warranty card
cover
Tool
4x feet
Listen to what they say
Disclaimer
Electricity cost savings, CO₂ reduction: Up to €1,797 per year and 3,932 kg CO₂:
Power generation:
According to data from MARSTEK's proprietary EMS platform, a 1000W solar panel in Southern Europe can generate up to 1,160 kWh annually. This product supports up to 4,000W of solar power, resulting in an annual generation of 1,160 × 4 = 4,640 kWh. Annual storage capacity: 15.36 kWh × 365 = 5,606.4 kWh.
Calculation assumptions:
Self-consumption rate: 85% ( source ); Fixed electricity price: €0.40/kWh; Difference between peak and low prices: €0.132/kWh; CO₂ reduction: Every 1 kWh of solar power reduces CO₂ emissions by approximately 0.997 kg ( source ).
Calculation details:
Annual electricity cost savings:
= Savings from self-consumption + Savings through AI-optimized charging
= 4,640 kWh × 85% × €0.40
+ (5,606.4 kWh − 4,640 kWh × 85%) × €0.132
≈ €1,797
- Estimated CO₂ reduction amount:
= 4,640 kWh × 85% × 0.997
≈ 3,932 kg
Note: Actual savings may vary depending on local solar radiation, actual electricity price, frequency of device usage, and individual electricity consumption.
Legal notice (Germany)
To benefit from the simplified exemption rules for plug-and-play solar power systems according to Section 8 Paragraph 5a EEG 2023:
- The installed PV capacity must be < 2000 Wp.
- The apparent power of the inverter must be ≤ 800 VA P.
If your total PV output exceeds 2,000 Wp, additional requirements may be imposed by the grid operator, e.g.:
a) Registration
b) Obligation to modify the meter
c) Formal approval procedures: Please inform yourself about the applicable local regulations before installation.
Plug & Play solar systems can generally be installed independently. However, in Germany, registration in the MaStR portal (www.marktstammdatenregister.de) is mandatory.
Commissioning and grid connection must be carried out by certified professionals. An electrician is legally required to ensure compliance with all regulations.
Ensuring compliance with regulations.
Disclaimer
Electricity cost savings, CO₂ reduction: Up to €1,797 per year and 3,932 kg CO₂:
Power generation:
According to data from MARSTEK's proprietary EMS platform, a 1000W solar panel in Southern Europe can generate up to 1,160 kWh annually. This product supports up to 4,000W of solar power, resulting in an annual generation of 1,160 × 4 = 4,640 kWh. Annual storage capacity: 15.36 kWh × 365 = 5,606.4 kWh.
Calculation assumptions:
Self-consumption rate: 85% ( source ); Fixed electricity price: €0.40/kWh; Difference between peak and low prices: €0.132/kWh; CO₂ reduction: Every 1 kWh of solar power reduces CO₂ emissions by approximately 0.997 kg ( source ).
Calculation details:
Annual electricity cost savings:
= Savings from self-consumption + Savings through AI-optimized charging
= 4,640 kWh × 85% × €0.40
+ (5,606.4 kWh − 4,640 kWh × 85%) × €0.132
≈ €1,797
- Estimated CO₂ reduction amount:
= 4,640 kWh × 85% × 0.997
≈ 3,932 kg
Note: Actual savings may vary depending on local solar radiation, actual electricity price, frequency of device usage, and individual electricity consumption.
Legal notice (Germany)
To benefit from the simplified exemption rules for plug-and-play solar power systems according to Section 8 Paragraph 5a EEG 2023:
- The installed PV capacity must be < 2000 Wp.
- The apparent power of the inverter must be ≤ 800 VA P.
If your total PV output exceeds 2,000 Wp, additional requirements may be imposed by the grid operator, e.g.:
a) Registration
b) Obligation to modify the meter
c) Formal approval procedures: Please inform yourself about the applicable local regulations before installation.
Plug & Play solar systems can generally be installed independently. However, in Germany, registration in the MaStR portal (www.marktstammdatenregister.de) is mandatory.
Commissioning and grid connection must be carried out by certified professionals. An electrician is legally required to ensure compliance with all regulations.
Ensuring compliance with regulations.